Seeing heat loss through a concrete wall

FLIR0032

The thermal image above (taken with a FLIR C2) illustrates heat loss through an uninsulated concrete foundation wall at floor level. The concrete foundation is insulated below grade, but the owner did not want to see insulation between the grade and the bottom of the siding. (The uninsulated concrete is a thermal bridge that connects interior heated space with outside winter conditions. Purchased heat is lost across this thermal bridge.)

The image below shows two conditions: Significant heat loss is visible through the exposed concrete wall on the right side of the photo. Just to the left of the exposed concrete, a previously exposed concrete block foundation wall has been insulated with 2 inches of stucco faced polystyrene, and the benefits are visible. The added insulation keeps the heat inside and improves interior comfort. (Insulating the concrete block wall also eliminated air infiltration paths through cracks at mortar joints.)

FLIR0036

Posted in Energy Efficiency

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>

CAUTION

The content provided on this site and in the Posts is intended to be entertaining, thought-provoking, and educational. It is not intended as direction or recommendations for the design or construction of any specific building project. The information is provided in good faith but without assurance as to its completeness, accuracy, or suitability for any particular purpose. If you are considering using information provided on this site, you are responsible for verifying its appropriateness to your needs, and you assume all risk for its use.